Share:


FUJI ELECTRIC ULTRASONIC FLOWMETER S-Flow



Easy Installation, Space Savings

Flow rate is “visualized” using our long-cultivated ultrasonic technologies.
Contributes to energy savings and production process solutions.

  • Easy Clamp-on type by simply tightening 4 screws.
    No need for pipe modification.
  • Integrated detector and flow transmitter for space savings.
  • Built-in temperature sensor enables simultaneous measurement of flow rate and temperature (Optional).

Specifications

Integral Ultrasonic Flowmeter S-Flow <FSZ>: Specifications
Main unit type Type Pipe diameter
FSZ08 8A, 10A
FSZ15 15A, 20A
FSZ25 25A, 32A
Scroll
scrollable
Configuration Integrated flow transmitter and detector
Mounting method Clamp-on type
Measurement method Transit-time measuring method
Fluid to measure Homogenous fluids where ultrasonic signals can be transmitted
Measurement range 0 to ±5 m/s (Min. 0 to ±0.2 m/s)
Accuracy Velocity 1 m/s to 5 m/s: ±2% of rate Velocity less than 1 m/s: ±0.02 m/s
Required straight pipe length Upstream 10D or more; Downstream 5D or more (D: Pipe inner diameter)
Pipe materials Metals (stainless steel, steel, copper) Plastics (PVC, PP, PVDF)
Piping thickness 1.2 mm to 4.9 mm
Fluid temperature -15 to +85°C (Can vary depending on ambient temperature)
Response time: 0.5 seconds
Output signal 4 to 20 mA DC: 1 point
Contact: 2 points
Display LED 4-digit 2-row display
Degree of protection IP65/IP67
Ambient tem- perature -15 to +60°C
Ambient humidity 95%RH or less
Power supply and power consumption 20 to 27.5 V DC, 2.5 W or less
Mass FSZ08: 400 g
FSZ15: 500 g
FSZ25: 600 g
Temperature measurement (Optional) Pipe surface temperature measurement

Integral Ultrasonic Flowmeter | S-Flow